Drum Pump Flow MeterModel FM2000 SeriesOperating Instructions
Table of ContentsSafety ...
SafetyALWAYS wear protective clothing, eye protection, and follow standard safety procedures when handling corrosive or personally harmful materials.
Section 1 - InstallationNOTE: Avoid exposing the LCD for prolonged periods to direct sunlight or the life of the LCD may be reduced.1. Determine whi
Changing display from Rate or TotalProgramming Menu Flow ChartCalibrationWhile the FM-2000 has been calibrated at the factory, field calibration is pos
For example, the specific gravity on the MSDS for 93% sulfuric acid is shown as 1.84. 8.33 pounds per gallon x 1.84 = 15.33 pounds per gallon (density)
d) When finished, press the button. The screen changes to the RATE 2 (“2” is in left corner of display) screen. Do no make changes on th
Section 4 - MaintenanceThe FM-2000 Series is engineered for low maintenance; however, some conditions can cause increased wear on the paddle and/or po
Section 6 - Spare PartsItem NumberQty. Description Part Number2 1 Hose barb adapter, polypropylene 1066012 1 Hose barb adapter, PVDF 106601-13 1 1” N